1、Why BESS Safety Matters&Recommended SolutionsWhat Youll Learn Hazards within an ESS Recommended Protection Strategies Introduction to Fike BlueTM Thermal runaway chemical reaction Electrical fire from charging equipment and switches Explosion from off gassing of batteries Vent gases from failing bat

2、teries,several hundred liters of gasses Misinformation for AHJs and decision makersCommon BESS Safety RisksThe Problem of Thermal Runaway An extremely dangerous and unpredictable exothermic chemical reaction within a li-ion cell Caused by a malfunction or damage to the cell that creates an internal

3、short across the separator layer Generates an intense amount of heat;accelerate the reaction Toxic and flammable gasses build up Cell ruptures Once the reaction starts within a single cell it cannot be stopped Can cause Cascading Thermal RunawayOff-Gassing&Explosion Risks In addition to the fire ris

4、k caused by thermal runaway,an explosion risk is created as well NFPA 855-“Explosion Control”Off-gassing isnt just an explosion risk,as the toxic fumes can force evacuations of nearby communitiesPerformance Review of Current Protection MethodsFirefighting Water&Sprinklers Requires potentially thousa

5、nds of gallons of water to control the fire Chemicals from battery cells run off into the groundwater and environment May cause arcing which can provide an ignition source for combustible gasses and vapors.Chemical Agents&Aerosols May degrade at extreme temperatures A ventilation system may push out

6、 the protective gases as the event continues Have a boiling point even lower than water;do not have a meaningful thermal capacity for absorbing heatContainment/“Let it Burn”If all batteries are allowed to burn,an exorbitant amount of toxic gas is released Many AHJs wont accept an ESS without a prote

word格式文档无特别注明外均可编辑修改,预览文件经过压缩,下载原文更清晰!
三个皮匠报告文库所有资源均是客户上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作商用。
1. **BESS核心风险**:锂电池热失控(不可逆、连锁反应)、电池爆炸(NFPA 855要求爆炸控制)、失效电池释放数百升有毒气体。 2. **现有防护缺陷**:水喷淋需数千加仑且污染环境;化学剂高温失效;"静燃"策略释放大量毒气,不被监管接受。 3. **Fike五层防护**: - **热管理(Fike Blue)**:唯一经第三方测试可阻断热失控,数分钟内终止反应; - **爆炸控制**:泄压、通风、气体检测(维持VOC/H₂浓度低于LFL 25%); - **早期预警**:DT温度电缆、烟雾/VOC检测; - **A级防火**:针对外部电子设备火灾(如SF-1230); - **测试验证**:通过电池危险分析(BHA)设计方案并提交监管。
**热失控有多危险?** **BESS如何防爆?** **Fike Blue如何测试?**